<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="de">
	<id>https://wiki.gude-systems.com/index.php?action=history&amp;feed=atom&amp;title=FAQ_EPC_SNMP_Engl</id>
	<title>FAQ EPC SNMP Engl - Versionsgeschichte</title>
	<link rel="self" type="application/atom+xml" href="https://wiki.gude-systems.com/index.php?action=history&amp;feed=atom&amp;title=FAQ_EPC_SNMP_Engl"/>
	<link rel="alternate" type="text/html" href="https://wiki.gude-systems.com/index.php?title=FAQ_EPC_SNMP_Engl&amp;action=history"/>
	<updated>2026-05-28T18:44:38Z</updated>
	<subtitle>Versionsgeschichte dieser Seite in Gude Systems GmbH</subtitle>
	<generator>MediaWiki 1.35.2</generator>
	<entry>
		<id>https://wiki.gude-systems.com/index.php?title=FAQ_EPC_SNMP_Engl&amp;diff=238&amp;oldid=prev</id>
		<title>Mb am 21. Juni 2013 um 11:57 Uhr</title>
		<link rel="alternate" type="text/html" href="https://wiki.gude-systems.com/index.php?title=FAQ_EPC_SNMP_Engl&amp;diff=238&amp;oldid=prev"/>
		<updated>2013-06-21T11:57:57Z</updated>

		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;table class=&quot;diff diff-contentalign-left diff-editfont-monospace&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;de&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Nächstältere Version&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Version vom 21. Juni 2013, 11:57 Uhr&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l185&quot; &gt;Zeile 185:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Zeile 185:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;=NET-SNMP=&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;=NET-SNMP=&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;−&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[http://net-snmp.sourceforge.net/ NET-SNMP] provides a widely used collection of SNMP command line tools (snmpget, snmpset, &lt;del class=&quot;diffchange diffchange-inline&quot;&gt;smnpwalk&lt;/del&gt;, etc.).&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[http://net-snmp.sourceforge.net/ NET-SNMP] provides a widely used collection of SNMP command line tools (snmpget, snmpset, &lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;snmpwalk&lt;/ins&gt;, etc.).&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;NET-SNMP is available for Linux and Windows.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;NET-SNMP is available for Linux and Windows.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>Mb</name></author>
	</entry>
	<entry>
		<id>https://wiki.gude-systems.com/index.php?title=FAQ_EPC_SNMP_Engl&amp;diff=56&amp;oldid=prev</id>
		<title>Mb: Die Seite wurde neu angelegt: „=General= *SNMP can be used on an '''EPC'''  ** to get UDP (Port 161) Status and Sensor informations ** to switch Powerports  For a complete list of possible S…“</title>
		<link rel="alternate" type="text/html" href="https://wiki.gude-systems.com/index.php?title=FAQ_EPC_SNMP_Engl&amp;diff=56&amp;oldid=prev"/>
		<updated>2013-03-07T18:29:46Z</updated>

		<summary type="html">&lt;p&gt;Die Seite wurde neu angelegt: „=General= *SNMP can be used on an &amp;#039;&amp;#039;&amp;#039;EPC&amp;#039;&amp;#039;&amp;#039;  ** to get UDP (Port 161) Status and Sensor informations ** to switch Powerports  For a complete list of possible S…“&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Neue Seite&lt;/b&gt;&lt;/p&gt;&lt;div&gt;=General=&lt;br /&gt;
*SNMP can be used on an '''EPC''' &lt;br /&gt;
** to get UDP (Port 161) Status and Sensor informations&lt;br /&gt;
** to switch Powerports&lt;br /&gt;
&lt;br /&gt;
For a complete list of possible SNMP requests and actions go ito the ''Webinterface'' of the '''EPC''' and enter the '''Configuration - SNMP''' menu. There you find the link ''Download SNMP MIB''.&lt;br /&gt;
&lt;br /&gt;
For all devices of the '''Expert Power Control NET''' series applies:&lt;br /&gt;
&lt;br /&gt;
*supported SNMP Versions: '''SNMPv1''' und '''SNMPv2c'''&lt;br /&gt;
*supported SNMP Commands:&lt;br /&gt;
**'''SNMPGET''' : request Status- and Sensor informations&lt;br /&gt;
**'''SNMPGETNEXT''' : request next Status information&lt;br /&gt;
**'''SNMPSET''' : request EPC state change&lt;br /&gt;
&lt;br /&gt;
*To query the EPC via SNMP, you need a '''N'''etwork'''M'''anagment'''S'''ystem, like e.g. [http://h20229.www2.hp.com/ HP-OpenView], [http://www.opennms.org/ OpenNMS], [http://www.nagios.org/ Nagios], etc... or simple command line tools like e.g. [http://net-snmp.sourceforge.net/ NET-SNMP] that are used in the following examples.&lt;br /&gt;
&lt;br /&gt;
=SNMP Communities=&lt;br /&gt;
SNMP authenticates the network requests by so-called communities. Every SNMP get request (read access) has to be accompanied with a '''public''' community, and every condition change request (write access) needs a '''private''' community send along. The SNMP communities are, so to speak, '''read and write passwords'''. In SNMP versions v1 and v2c the communities are sent '''unencrypted across the network''' and can therefore easily be intercepted with IP sniffers. We recommend to use SNMP in a DMZ [http://en.wikipedia.org/wiki/DMZ_%28computing%29 demilitarized zone] or use the [[FAQ EPC IP ACL | IP ACL]] for access control!&lt;br /&gt;
&lt;br /&gt;
=MIBs=&lt;br /&gt;
The values that can be read or written, the so-called 'Managed Objects', are arranged in '''M'''anagement '''I'''nformation '''B'''ases (short MIBs). Three different types of Objects can be queried:&lt;br /&gt;
*system&lt;br /&gt;
*interface&lt;br /&gt;
*powerports&lt;br /&gt;
''system'' und ''interface'' are standardized MIB's (MIB-II), the ''powerports'' structure is in the enterprise part of the  MIB (GUDEADS-EPC-MIB::gadsEPC) that was constructed especially for the EPC. Subordinated to these three structures are the OIDs (Object Identifiers).&lt;br /&gt;
An OID represents the location of a value inside the MIB. Each OID may alternatively be referred to with its symbol name (''subtree name'').&lt;br /&gt;
&lt;br /&gt;
The following example tables apply for the '''Expert Power Control NET 8x Rev. 2 ''' or the '''Expert Power Control NET 8x 8010 '''&lt;br /&gt;
&lt;br /&gt;
===system===&lt;br /&gt;
{| cellpadding=&amp;quot;5&amp;quot; cellspacing=&amp;quot;0&amp;quot; border=&amp;quot;1&amp;quot;&lt;br /&gt;
|- style=&amp;quot;background-color:#f0f0f0; font-style:bold;&amp;quot;&lt;br /&gt;
|subtree name&lt;br /&gt;
|OID&lt;br /&gt;
|-&lt;br /&gt;
|system&lt;br /&gt;
|[http://www.alvestrand.no/objectid/1.3.6.1.2.1.1.html 1.3.6.1.2.1.1]&lt;br /&gt;
|-&lt;br /&gt;
|sysDescr&lt;br /&gt;
|[http://www.alvestrand.no/objectid/1.3.6.1.2.1.1.1.html 1.3.6.1.2.1.1.1]&lt;br /&gt;
|-&lt;br /&gt;
|sysObjectID&lt;br /&gt;
|[http://www.alvestrand.no/objectid/1.3.6.1.2.1.1.2.html 1.3.6.1.2.1.1.2]&lt;br /&gt;
|-&lt;br /&gt;
|sysUpTime&lt;br /&gt;
|[http://www.alvestrand.no/objectid/1.3.6.1.2.1.1.3.html 1.3.6.1.2.1.1.3]&lt;br /&gt;
|-&lt;br /&gt;
|sysContact&lt;br /&gt;
|[http://www.alvestrand.no/objectid/1.3.6.1.2.1.1.4.html 1.3.6.1.2.1.1.4]&lt;br /&gt;
|-&lt;br /&gt;
|sysName&lt;br /&gt;
|[http://www.alvestrand.no/objectid/1.3.6.1.2.1.1.5.html 1.3.6.1.2.1.1.5]&lt;br /&gt;
|-&lt;br /&gt;
|sysLocation&lt;br /&gt;
|[http://www.alvestrand.no/objectid/1.3.6.1.2.1.1.6.html 1.3.6.1.2.1.1.6]&lt;br /&gt;
|-&lt;br /&gt;
|sysServices&lt;br /&gt;
|[http://www.alvestrand.no/objectid/1.3.6.1.2.1.1.7.html 1.3.6.1.2.1.1.7]&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
===interface===&lt;br /&gt;
{| cellpadding=&amp;quot;5&amp;quot; cellspacing=&amp;quot;0&amp;quot; border=&amp;quot;1&amp;quot;&lt;br /&gt;
|- style=&amp;quot;background-color:#f0f0f0; font-style:bold;&amp;quot;&lt;br /&gt;
|subtree name&lt;br /&gt;
|OID&lt;br /&gt;
|-&lt;br /&gt;
|ifIndex&lt;br /&gt;
|[http://www.alvestrand.no/objectid/1.3.6.1.2.1.2.2.1.1.html 1.3.6.1.2.1.2.2.1.1]&lt;br /&gt;
|-&lt;br /&gt;
|ifDescr&lt;br /&gt;
|[http://www.alvestrand.no/objectid/1.3.6.1.2.1.2.2.1.2.html 1.3.6.1.2.1.2.2.1.2]&lt;br /&gt;
|-&lt;br /&gt;
|ifType&lt;br /&gt;
|[http://www.alvestrand.no/objectid/1.3.6.1.2.1.2.2.1.3.html 1.3.6.1.2.1.2.2.1.3]&lt;br /&gt;
|-&lt;br /&gt;
|ifMtu&lt;br /&gt;
|[http://www.alvestrand.no/objectid/1.3.6.1.2.1.2.2.1.4.html 1.3.6.1.2.1.2.2.1.4]&lt;br /&gt;
|-&lt;br /&gt;
|ifSpeed&lt;br /&gt;
|[http://www.alvestrand.no/objectid/1.3.6.1.2.1.2.2.1.5.html 1.3.6.1.2.1.2.2.1.4]&lt;br /&gt;
|-&lt;br /&gt;
|ifPhysAddress&lt;br /&gt;
|[http://www.alvestrand.no/objectid/1.3.6.1.2.1.2.2.1.6.html 1.3.6.1.2.1.2.2.1.6]&lt;br /&gt;
|-&lt;br /&gt;
|ifAdminStatus&lt;br /&gt;
|[http://www.alvestrand.no/objectid/1.3.6.1.2.1.2.2.1.7.html 1.3.6.1.2.1.2.2.1.7]&lt;br /&gt;
|-&lt;br /&gt;
|ifOperStatus&lt;br /&gt;
|[http://www.alvestrand.no/objectid/1.3.6.1.2.1.2.2.1.8.html 1.3.6.1.2.1.2.2.1.8]&lt;br /&gt;
|-&lt;br /&gt;
|ifLastChange&lt;br /&gt;
|[http://www.alvestrand.no/objectid/1.3.6.1.2.1.2.2.1.9.html 1.3.6.1.2.1.2.2.1.9]&lt;br /&gt;
|-&lt;br /&gt;
|ifInOctets&lt;br /&gt;
|[http://www.alvestrand.no/objectid/1.3.6.1.2.1.2.2.1.10.html 1.3.6.1.2.1.2.2.1.10]&lt;br /&gt;
|-&lt;br /&gt;
|ifInUcastPkt&lt;br /&gt;
|[http://www.alvestrand.no/objectid/1.3.6.1.2.1.2.2.1.11.html 1.3.6.1.2.1.2.2.1.11]&lt;br /&gt;
|-&lt;br /&gt;
|ifInNUcastPkts&lt;br /&gt;
|[http://www.alvestrand.no/objectid/1.3.6.1.2.1.2.2.1.12.html 1.3.6.1.2.1.2.2.1.12]&lt;br /&gt;
|-&lt;br /&gt;
|ifInDiscards&lt;br /&gt;
|[http://www.alvestrand.no/objectid/1.3.6.1.2.1.2.2.1.13.html 1.3.6.1.2.1.2.2.1.13]&lt;br /&gt;
|-&lt;br /&gt;
|ifInErrors&lt;br /&gt;
|[http://www.alvestrand.no/objectid/1.3.6.1.2.1.2.2.1.14.html 1.3.6.1.2.1.2.2.1.14]&lt;br /&gt;
|-&lt;br /&gt;
|ifInUnknownProtos&lt;br /&gt;
|[http://www.alvestrand.no/objectid/1.3.6.1.2.1.2.2.1.15.html 1.3.6.1.2.1.2.2.1.15]&lt;br /&gt;
|-&lt;br /&gt;
|ifOutOctets&lt;br /&gt;
|[http://www.alvestrand.no/objectid/1.3.6.1.2.1.2.2.1.16.html 1.3.6.1.2.1.2.2.1.16]&lt;br /&gt;
|-&lt;br /&gt;
|ifOutUcastPkts&lt;br /&gt;
|[http://www.alvestrand.no/objectid/1.3.6.1.2.1.2.2.1.17.html 1.3.6.1.2.1.2.2.1.17]&lt;br /&gt;
|-&lt;br /&gt;
|ifOutNUcastPkts&lt;br /&gt;
|[http://www.alvestrand.no/objectid/1.3.6.1.2.1.2.2.1.18.html 1.3.6.1.2.1.2.2.1.18]&lt;br /&gt;
|-&lt;br /&gt;
|ifOutDiscards&lt;br /&gt;
|[http://www.alvestrand.no/objectid/1.3.6.1.2.1.2.2.1.19.html 1.3.6.1.2.1.2.2.1.19]&lt;br /&gt;
|-&lt;br /&gt;
|ifOutErrors&lt;br /&gt;
|[http://www.alvestrand.no/objectid/1.3.6.1.2.1.2.2.1.20.html 1.3.6.1.2.1.2.2.1.20]&lt;br /&gt;
|-&lt;br /&gt;
|ifOutQLen&lt;br /&gt;
|[http://www.alvestrand.no/objectid/1.3.6.1.2.1.2.2.1.21.html 1.3.6.1.2.1.2.2.1.21]&lt;br /&gt;
|-&lt;br /&gt;
|ifSpecific&lt;br /&gt;
|[http://www.alvestrand.no/objectid/1.3.6.1.2.1.2.2.1.22.html 1.3.6.1.2.1.2.2.1.22]&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
===powerports===&lt;br /&gt;
{| cellpadding=&amp;quot;5&amp;quot; cellspacing=&amp;quot;0&amp;quot; border=&amp;quot;1&amp;quot;&lt;br /&gt;
|- style=&amp;quot;background-color:#f0f0f0; font-style:bold;&amp;quot;&lt;br /&gt;
|subtree name&lt;br /&gt;
|OID&lt;br /&gt;
|description&lt;br /&gt;
|r / w&lt;br /&gt;
|-&lt;br /&gt;
|GUDEADS-EPC-MIB&lt;br /&gt;
|1.3.6.1.4.1.28507&lt;br /&gt;
|Gude Analog- und Digitsysteme GmbH MIB (Private Enterprise)&lt;br /&gt;
|r&lt;br /&gt;
|-&lt;br /&gt;
|GUDEADS-EPC-MIB::gadsEPC8&lt;br /&gt;
|1.3.6.1.4.1.28507.1&lt;br /&gt;
|Expert Power Control MIB&lt;br /&gt;
|r&lt;br /&gt;
|-&lt;br /&gt;
|epc8powerports&lt;br /&gt;
|1.3.6.1.4.1.28507.1.1.2&lt;br /&gt;
|Expert Power Control's Powerports&lt;br /&gt;
|r&lt;br /&gt;
|-&lt;br /&gt;
|epc8portNumber&lt;br /&gt;
|1.3.6.1.4.1.28507.1.1.2.1&lt;br /&gt;
|total number of powerports&lt;br /&gt;
|r&lt;br /&gt;
|-&lt;br /&gt;
|epc8portTable&lt;br /&gt;
|1.3.6.1.4.1.28507.1.1.2.2&lt;br /&gt;
|Expert Power Control's Powerports SMI-Table&lt;br /&gt;
|r&lt;br /&gt;
|-&lt;br /&gt;
|epc8powerPortName&lt;br /&gt;
|1.3.6.1.4.1.28507.1.1.2.2.1.2&lt;br /&gt;
|A textual string containing name of a PowerPort.&lt;br /&gt;
|r&lt;br /&gt;
|-&lt;br /&gt;
|epc8powerPortState&lt;br /&gt;
|1.3.6.1.4.1.28507.1.1.2.2.1.3&lt;br /&gt;
|current state a PowerPort (0=off, 1=on)&lt;br /&gt;
|rw&lt;br /&gt;
|-&lt;br /&gt;
|epc8powerPortSwitchCount&lt;br /&gt;
|1.3.6.1.4.1.28507.1.1.2.2.1.4&lt;br /&gt;
|total number of switch actions occurred on a powerPort.&lt;br /&gt;
|r&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
=NET-SNMP=&lt;br /&gt;
[http://net-snmp.sourceforge.net/ NET-SNMP] provides a widely used collection of SNMP command line tools (snmpget, snmpset, smnpwalk, etc.).&lt;br /&gt;
NET-SNMP is available for Linux and Windows.&lt;br /&gt;
&lt;br /&gt;
After the installation of NET-SNMP you should put the [http://www.gudeads.com/files/software/GUDEADS-EPC-MIB.txt device specific MIB of the EPC] in net-snmp's '''share''' directory, e.g. in&lt;br /&gt;
 c:\usr\share\snmp\mibs&lt;br /&gt;
or&lt;br /&gt;
 /usr/share/snmp/mibs&lt;br /&gt;
So you can later use the 'subtree names' instead of the OID's:&lt;br /&gt;
&lt;br /&gt;
*subtree names&lt;br /&gt;
 snmpwalk -v2c -mALL -c public 192.168.1.232 epc8powerports&lt;br /&gt;
&lt;br /&gt;
*OID&lt;br /&gt;
 snmpwalk -v2c -mALL -c public 192.168.1.232 1.3.6.1.4.1.28507&lt;br /&gt;
&lt;br /&gt;
=EPC Setup=&lt;br /&gt;
http://www.gudeads.com/wiki/images/epc_v2.2_config_snmp.jpg&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
----&lt;br /&gt;
&lt;br /&gt;
=Examples=&lt;br /&gt;
==walk system oids==&lt;br /&gt;
 snmpwalk -v2c -mALL -c public 192.168.1.232 system&lt;br /&gt;
&lt;br /&gt;
 SNMPv2-MIB::sysDescr.0 = STRING: ExpertPowerControl NET 8x&lt;br /&gt;
 SNMPv2-MIB::sysObjectID.0 = OID: GUDEADS-EPC-MIB::gadsEPC&lt;br /&gt;
 DISMAN-EXPRESSION-MIB::sysUpTimeInstance = Timeticks: (293200) 0:48:52.00&lt;br /&gt;
 SNMPv2-MIB::sysContact.0 = STRING: http://www.gudeads.com/&lt;br /&gt;
 SNMPv2-MIB::sysName.0 = STRING: ExpPowerControl&lt;br /&gt;
 SNMPv2-MIB::sysLocation.0 = STRING: &lt;br /&gt;
 SNMPv2-MIB::sysServices.0 = INTEGER: 0&lt;br /&gt;
&lt;br /&gt;
==walk interface oids==&lt;br /&gt;
 snmpwalk -v2c -mALL -c public 192.168.1.232 interfaces&lt;br /&gt;
&lt;br /&gt;
 RFC1213-MIB::interfaces.0.0 = INTEGER: 1&lt;br /&gt;
 RFC1213-MIB::ifIndex.1 = INTEGER: 1&lt;br /&gt;
 RFC1213-MIB::ifDescr.1 = STRING: &amp;quot;eth_cf52235&amp;quot;&lt;br /&gt;
 RFC1213-MIB::ifType.1 = INTEGER: ethernet-csmacd(6)&lt;br /&gt;
 RFC1213-MIB::ifMtu.1 = INTEGER: 1500&lt;br /&gt;
 RFC1213-MIB::ifSpeed.1 = Gauge32: 10000&lt;br /&gt;
 RFC1213-MIB::ifPhysAddress.1 = Hex-STRING: 00 19 32 00 00 07 &lt;br /&gt;
 RFC1213-MIB::ifAdminStatus.1 = INTEGER: up(1)&lt;br /&gt;
 RFC1213-MIB::ifOperStatus.1 = INTEGER: up(1)&lt;br /&gt;
 RFC1213-MIB::ifLastChange.1 = Wrong Type (should be Timeticks): INTEGER: 0&lt;br /&gt;
 RFC1213-MIB::ifInOctets.1 = Counter32: 450378&lt;br /&gt;
 RFC1213-MIB::ifInUcastPkts.1 = Counter32: 661&lt;br /&gt;
 RFC1213-MIB::ifInNUcastPkts.1 = Counter32: 3254&lt;br /&gt;
 RFC1213-MIB::ifInDiscards.1 = Counter32: 0&lt;br /&gt;
 RFC1213-MIB::ifInErrors.1 = Counter32: 0&lt;br /&gt;
 RFC1213-MIB::ifInUnknownProtos.1 = Counter32: 0&lt;br /&gt;
 RFC1213-MIB::ifOutOctets.1 = Counter32: 255309&lt;br /&gt;
 RFC1213-MIB::ifOutUcastPkts.1 = Counter32: 591&lt;br /&gt;
 RFC1213-MIB::ifOutNUcastPkts.1 = Counter32: 6&lt;br /&gt;
 RFC1213-MIB::ifOutDiscards.1 = Counter32: 0&lt;br /&gt;
 RFC1213-MIB::ifOutErrors.1 = Counter32: 594&lt;br /&gt;
 RFC1213-MIB::ifOutQLen.1 = Gauge32: 0&lt;br /&gt;
 RFC1213-MIB::ifSpecific.1 = OID: SNMPv2-SMI::zeroDotZero.0&lt;br /&gt;
&lt;br /&gt;
==walk powerports==&lt;br /&gt;
 snmpwalk -v2c -mALL -c public 192.168.1.232 epc8powerports&lt;br /&gt;
&lt;br /&gt;
 GUDEADS-EPC-MIB::epc8portNumber = INTEGER: 8&lt;br /&gt;
 GUDEADS-EPC-MIB::epc8powerPortName.1 = STRING: &amp;quot;SwitchPort 1&amp;quot;&lt;br /&gt;
 GUDEADS-EPC-MIB::epc8powerPortName.2 = STRING: &amp;quot;SwitchPort 2&amp;quot;&lt;br /&gt;
 GUDEADS-EPC-MIB::epc8powerPortName.3 = STRING: &amp;quot;SwitchPort 3&amp;quot;&lt;br /&gt;
 GUDEADS-EPC-MIB::epc8powerPortName.4 = STRING: &amp;quot;SwitchPort 4&amp;quot;&lt;br /&gt;
 GUDEADS-EPC-MIB::epc8powerPortName.5 = STRING: &amp;quot;SwitchPort 5&amp;quot;&lt;br /&gt;
 GUDEADS-EPC-MIB::epc8powerPortName.6 = STRING: &amp;quot;SwitchPort 6&amp;quot;&lt;br /&gt;
 GUDEADS-EPC-MIB::epc8powerPortName.7 = STRING: &amp;quot;SwitchPort 7&amp;quot;&lt;br /&gt;
 GUDEADS-EPC-MIB::epc8powerPortName.8 = STRING: &amp;quot;SwitchPort 8&amp;quot;&lt;br /&gt;
 GUDEADS-EPC-MIB::epc8powerPortState.1 = INTEGER: on(1)&lt;br /&gt;
 GUDEADS-EPC-MIB::epc8powerPortState.2 = INTEGER: on(1)&lt;br /&gt;
 GUDEADS-EPC-MIB::epc8powerPortState.3 = INTEGER: off(0)&lt;br /&gt;
 GUDEADS-EPC-MIB::epc8powerPortState.4 = INTEGER: off(0)&lt;br /&gt;
 GUDEADS-EPC-MIB::epc8powerPortState.5 = INTEGER: off(0)&lt;br /&gt;
 GUDEADS-EPC-MIB::epc8powerPortState.6 = INTEGER: off(0)&lt;br /&gt;
 GUDEADS-EPC-MIB::epc8powerPortState.7 = INTEGER: off(0)&lt;br /&gt;
 GUDEADS-EPC-MIB::epc8powerPortState.8 = INTEGER: off(0)&lt;br /&gt;
 GUDEADS-EPC-MIB::epc8powerPortSwitchCount.1 = Counter32: 5&lt;br /&gt;
 GUDEADS-EPC-MIB::epc8powerPortSwitchCount.2 = Counter32: 1&lt;br /&gt;
 GUDEADS-EPC-MIB::epc8powerPortSwitchCount.3 = Counter32: 0&lt;br /&gt;
 GUDEADS-EPC-MIB::epc8powerPortSwitchCount.4 = Counter32: 0&lt;br /&gt;
 GUDEADS-EPC-MIB::epc8powerPortSwitchCount.5 = Counter32: 0&lt;br /&gt;
 GUDEADS-EPC-MIB::epc8powerPortSwitchCount.6 = Counter32: 0&lt;br /&gt;
 GUDEADS-EPC-MIB::epc8powerPortSwitchCount.7 = Counter32: 0&lt;br /&gt;
 GUDEADS-EPC-MIB::epc8powerPortSwitchCount.8 = Counter32: 0&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
==Query the Powerport 1 state==&lt;br /&gt;
 snmpget -v2c -mALL -c private 192.168.1.232 epc8powerPortState.1&lt;br /&gt;
&lt;br /&gt;
 GUDEADS-EPC-MIB::epc8powerPortState.1 = INTEGER: on(1)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
==Turn Powerport 1 on==&lt;br /&gt;
 snmpset -v2c -mALL -c private 192.168.1.232 epc8powerPortState.1  integer 1&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=downloads=&lt;br /&gt;
*[http://net-snmp.sourceforge.net/ NET-SNMP]&lt;br /&gt;
&lt;br /&gt;
All MIB-Tables can be accessed directly from the device. Under&lt;br /&gt;
 http://[device IP]/config_snmp.html&lt;br /&gt;
click on the Link &amp;quot;'''Download SNMP MIB'''&amp;quot;. The device specific MIB will be shown.&lt;br /&gt;
&lt;br /&gt;
Example-MIBs:&lt;br /&gt;
*[http://www.gudeads.com/files/software/GUDEADS-EPC8X-MIB.txt GUDEADS-EPC8X-MIB.txt]&lt;br /&gt;
*[http://www.gudeads.com/files/software/GUDEADS-EPC24X-MIB.txt GUDEADS-EPC24X-MIB.txt]&lt;br /&gt;
&lt;br /&gt;
=Glossary=&lt;br /&gt;
*[http://de.wikipedia.org/wiki/Snmp SNMP, MIBs]&lt;br /&gt;
*[http://de.wikipedia.org/wiki/Object_Identifier OID]&lt;/div&gt;</summary>
		<author><name>Mb</name></author>
	</entry>
</feed>